Using The Dtmf Decoder; Measurement Limits - HP 8920A User Manual

Rf communications test set
Hide thumbs Also See for 8920A:
Table of Contents

Advertisement

Chapter 8, Signaling Decoder Screen

Using the DTMF Decoder

Using the DTMF Decoder

Measurement Limits

294
S:\HP892XX\USRGUIDE\manual\decoscrn.fb
680 - 960 Hz
Lo Tone:
1190 - 1660 Hz
Hi Tone:
Actual limits are typically slightly wider than this. However, the crossover point
between Hi and Lo tone decoding is approximately 1.1 kHz. If incoming tones
approach this point, unreliable measurements may be displayed (frequency
measurement errors and spurious off times).