Returned Format
:CHANnel<N>:DPRocessing:FILTer:SCALe
Returned Format
:CHANnel<N>:DPRocessing:FILTer:STATe
Returned Format
Keysight M8131A 16/32 GSa/s Digitizer User's Guide
The query returns the default values for the coefficients for the correction
filter for the specified channel. If the optional parameter of sample rate
mode is given, it returns the default filter values for the specified sample
rate otherwise for the current sample rate mode.
[:CHANnel<N>:DPRocessing:FILTer:DEFault] <filter_values> <NL>
Command
:CHANnel<N>:DPRocessing:FILTer:SCALe <scale>
Description
The command sets the correction filter scaling factor for a channel.
<N> An integer, 1-4
<scale>
The correction filter scaling factor between 0 and 2.
Query
:CHANnel<N>:DPRocessing:FILTer:SCALe?
The query returns the current correction filter scaling factor for a channel.
[:CHANnel<N>:DPRocessing:FILTer:SCALe] <scale> <NL>
Command
:CHANnel<N>:DPRocessing:FILTer:STATe {ON | 1} | {OFF |
0}
Description
The command sets the state of the correction filter - on or off.
<N> An integer, 1-4
Query
:CHANnel<N>:DPRocessing:FILTer:STATe?
The query returns the current state of the correction filter for a channel.