02 | Keysight | PXI Vector Network Analyzer - Configuration Guide Drive Down the Size of Test This configuration guide describes standard configurations, options, accessories, upgrade kits and compatible peripherals for the M937xA PXIe vector network analyzer (VNA). This guide should be used with the Keysight PXI VNA data sheet for a complete description of these analyzers.
03 | Keysight | PXI Vector Network Analyzer - Configuration Guide A. Select Options for M937xA PXIe VNA Step 1. Start by choosing the frequency range of the M937xA PXIe VNA – M9370A 300 kHz to 4 GHz – – M9371A 300 kHz to 6.5 GHz...
05 | Keysight | PXI Vector Network Analyzer - Configuration Guide C. Select Controller (Via PC) To use your Laptop PC as a controller – M9045B PCIe ExpressCard adaptor – Y1200B PCIe cable – M9021A PCIe cable interface : 1 slot To use your Desktop PC as a controller –...
08 | Keysight | PXI Vector Network Analyzer - Configuration Guide F. Select Software for M937xA PXIe VNA Step 1. Start with M937xA base configuration The M937xA comes standard with the following software: – Keysight IO Libraries Suite including Connection Expert –...
09 | Keysight | PXI Vector Network Analyzer - Configuration Guide G. Select Services: Calibration, Start-up Assistance – M937xA -UK6 Commercial calibration certification with Complete set of measurements which tests unit to manufac- test data turer’s published specifications. Includes calibration label, calibration certificate, and data report.
10 | Keysight | PXI Vector Network Analyzer - Configuration Guide H. Measurement Accessories Calibration kits Coaxial measurements A complete list of RF and microwave test accessories is available www.keysight.com/find/mta. on our web site: Mechanical calibration kits include standards, such as opens, shorts and loads, which are measured by the network analyzer for Accessories are available in these connector types: 50 ohm increased measurement accuracy.
11 | Keysight | PXI Vector Network Analyzer - Configuration Guide For devices with 3.5 mm or SMA connectors Option M0F with: 85093-60008 3.5 mm (f) to 3.5 mm (m) ECal module Mechanical calibration kits Option 00F module with: 85093-60010 3.5 mm (f) to 3.5 mm (f) ECal module –...
13 | Keysight | PXI Vector Network Analyzer - Configuration Guide For devices with 7 mm connectors For devices with waveguide Mechanical calibration kits Mechanical calibration kits – 85050B Standard, DC to 18 GHz X Band Includes: – X11644A Standard WR-90, 8.2 to 12.4 GHz 00909-60008 7 mm coax termination Includes: 85050-60006 7 mm fixed broadband load...
The frequency of the multiport array is determined by the lowest frequency module configured in the array. For example, a 4-port analyzer configuration using an M9370A (4 GHz) and an M9375A (26.5 GHz) would have a maximum frequency of 4 GHz when performing 4-port measurements.
The Y1242A multiport cable kit only needs to be ordered when modules are used in a multiport configuration. Upgrading your system Your product can be easily upgraded after the initial purchase. Contact your Keysight representative to place an order for an option upgrade. Order for existing model number M9370A M9371A M9372A M9373A M9374A M9375A Extend analyzer’s frequency range to 6.5 GHz...
M9019A PXIe 18 slot Chassis, Data Sheet, 5992-1481EN M9037A PXIe High Performance Embedded Controller, Data Sheet, 5991-3661EN M9036A PXIe Embedded Controller, Data Sheet, 5990-8465EN 1. For a list of computers compatible with Keysight Technologies PXIe M9018A chassis, refer to Tested Computer Technical Note (literature no. 5990-7632EN). www.keysight.com/find/pxivna...