11. REPLACING FUSES

WARNING
・ Before removing the fuse holder and fuses, be sure that the Main Power Switch ⑨ is turned OFF
and the Power Cord Connector has been removed from the CONTROLLER.
・ Verify type and use only following the properly rated and type of fuse.
  Specified fuses : T
* Failure to use the proper type and rated fuse will result in fire, injury, electric shock and / or
product damage.
(1) Push on the clips on the top and bottom of the fuse holder and
remove the fuse holder block.
(2) Remove the bad fuse or fuses and replace with the proper type
and rating of fuse by the input voltage being used.
(3) Replace the fuse holder containing the fuses into the Main Power
Inlet with Power Supply Fuses ⑩ and make sure it snaps in
place.

12. CONTROLLER MOUNTING BRACKET INSTALLATION

CAUTION
・ If there is a possibility for the CONTROLLER to move from its mounting location, for safety, be sure
to secure it with the brackets provided.
・ When installing the CONTROLLER, be sure to place air vents downward, away from debris. Protect
the CONTROLLER (air vents and other connector) from cutting oil, mist oil, powder dust, other
contaminants that can buildup heat and damage the internal components of the CONTROLLER.
・ The Bracket can be installed on the " Bottom Mounting (Fig. 13) " and " Rear Mounting (Fig. 14) " of
the CONTROLLER.
(1) Attach the Installation Brackets (2pcs.) using the provided Mounting Screws (6pcs.).
(2) Attach the CONTROLLER (Bracket's Slotted Area) to the machine using the provided Mounting Screws (6pcs.).
Bottom Mounting
70
5 A ( 250 V) Part No. S 506 - 5 -R (Cooper Bussman Inc.)
Slotted Area
Bracket
Fig. 13
Fig. 12
Rear Mounting
Slotted Area
Bracket
Fig. 14