18 - 3 Contents of Parameters
CAUTION
The operating parameters can be preset depending on the application requirements. Please operate only
after confirming contents of parameter settings.
The following parameters can be set.
①
Setting of Error Output Mode
・Selection of the error output mode is on " Error (Pin No. 8 : ERR) " of Input / Output Connector A ③.
・When an error occurs the output can be select to ' ON (Closed) ' or ' OFF (Open) '.
・Signals can be output according to the required machine control logic of the system.
Table. 11
Parameter
②
Setting AUTO Mode for Motor Speed Control
・ Allows the setting of the manner in which Motor speed can be controlled when the system is being used in the
Controls' AUTO MODE (External Command Signal Control).
・ This parameter selects between speed control with the Motor Speed Adjustment Button (SPEED
the Control Panel ② or by External Command Signal through Input / Output Connector A ③.
Table. 12
Parameter
③
Setting Fixed Motor No. 1 Speed
CAUTION
If you set the rotation speed higher than the rotation speed set at
according to
.
・ Allows the Motor No. 1 speed to be fixed. Settable Motor Speed Range is 1,000 - 50,000min
increments.
・Proactively prevents inadvertent change in speed.
・The Fixed Motor Speed can set by Control Mode MANUAL or AUTO.
Table. 13
Parameter
98
Set Contents
Error Occurred : Signal is ' OFF (Open) '.
Error Occurred : Signal is ' ON (Closed) '.
Set Contents
Set the Motor Rotation Speed by External Command Signal
through External Input / Output Connector A ③ .
Set the Motor Rotation Speed by Motor Speed Adjustment Button
(SPEED
,
) ⑮ via the Control Panel ② .
Set Contents
Fixed Motor Speed for Motor No. 1 is disabled.
Fixed Motor Speed for Motor No. 1 is enabled.
,
, rotation speed will be set
-1
in 1,000min
) ⑮ of
-1