Nakanishi E2280 Operation Manual page 43

Table of Contents

Advertisement

18 - 3 Contents of Parameters
CAUTION
The operating parameters can be preset depending on the application requirements. Please operate only
after confirming contents of parameter settings.
The following parameters can be set.
Setting of Error Output Mode
・Selection of the error output mode is on " Error (Pin No. 8 : ERR) " of Input / Output Connector A ③.
・When an error occurs the output can be select to ' ON (Closed) ' or ' OFF (Open) '.
・Signals can be output according to the required machine control logic of the system.
Table. 11
Parameter
Setting AUTO Mode for Motor Speed Control
・ Allows the setting of the manner in which Motor speed can be controlled when the system is being used in the
Controls' AUTO MODE (External Command Signal Control).
・ This parameter selects between speed control with the Motor Speed Adjustment Button (SPEED
the Control Panel ② or by External Command Signal through Input / Output Connector A ③.
Table. 12
Parameter
Setting Fixed Motor No. 1 Speed
CAUTION
If you set the rotation speed higher than the rotation speed set at
according to
.
・ Allows the Motor No. 1 speed to be fixed. Settable Motor Speed Range is 1,000 - 50,000min
increments.
・Proactively prevents inadvertent change in speed.
・The Fixed Motor Speed can set by Control Mode MANUAL or AUTO.
Table. 13
Parameter
98
Set Contents
Error Occurred : Signal is ' OFF (Open) '.
Error Occurred : Signal is ' ON (Closed) '.
Set Contents
Set the Motor Rotation Speed by External Command Signal
through External Input / Output Connector A ③ .
Set the Motor Rotation Speed by Motor Speed Adjustment Button
(SPEED
,
) ⑮ via the Control Panel ② .
Set Contents
Fixed Motor Speed for Motor No. 1 is disabled.
Fixed Motor Speed for Motor No. 1 is enabled.
,
, rotation speed will be set
-1
in 1,000min
) ⑮ of
-1

Hide quick links: