7. If you desire to set other parameters, push the Motor Speed Adjustment Button (SPEED
select the parameter that needs to be set.
8. When you are finished setting parameters, turn the Main Power Switch ⑨ to OFF.
Selection of Air input Monitoring Override
Procedure
1. Push the START / STOP Button (START / STOP) ⑯ .
2.
is displayed. This indicates that supplying cooling air into the motor spindle and motor speed will
perform normally at start - up.
3. Push the START / STOP Button (START / STOP) ⑯ .
4.
is displayed. This indicates that without supplying cooling air, motor startup is possible with limited
speed.
5. You can cycle through the choices by pushing the START / STOP Button (START / STOP) ⑯ .
6. Push the Error Reset Button (RESET) ㉑ to send the settings to memory.
displayed.
7. If you desire to set other parameters, push the Motor Speed Adjustment Button (SPEED
select the parameter that needs to be set.
8. When you are finished setting parameters, turn the Main Power Switch ⑨ to OFF.
Selection of Motor Speed Control Voltage / DC+10V Signal Method
Procedure
1. Push the START / STOP Button (START / STOP) ⑯ .
2.
is displayed. The rotating speed can be set in range of 10,000 - 50,000min
3. Push the START / STOP Button (START / STOP) ⑯ .
4.
is displayed. The rotating speed can be set in range of 10,000 - 30,000min
5. You can cycle through the choices by pushing the START / STOP Button (START / STOP) ⑯ .
6. Push the Error Reset Button (RESET) ㉑ to send the settings to memory.
displayed.
7. If you desire to set other parameters, push the Motor Speed Adjustment Button (SPEED
select the parameter that needs to be set.
8. When you are finished setting parameters, turn the Main Power Switch ⑨ to OFF.
Selection of Emergency Stop Function
Procedure
1. Push the START / STOP Button (START / STOP) ⑯ .
2.
is displayed. This indicates that Emergency Stop Function cannot be used.
3. Push the START / STOP Button (START / STOP) ⑯ .
4.
is displayed. This indicates that Emergency Stop Function is active.
5. You can cycle through the choices by pushing the START / STOP Button (START / STOP) ⑯ .
6. Push the Error Reset Button (RESET) ㉑ to send the settings to memory.
displayed.
7. If you desire to set other parameters, push the Motor Speed Adjustment Button (SPEED
select the parameter that needs to be set.
8. When you are finished setting parameters, turn the Main Power Switch ⑨ to OFF.