Code
Types
Setting Maximum Motor No. 1
Speed
Setting Maximum Motor No. 2
Speed
Selection of External Speed
Control Mode
Selection of External Motor Start
Signal Control Mode
Selection of Air Input Monitoring
Override
Selection of Motor Speed Control
Voltage / DC+10V Signal Method
Selection of Emergency Stop
Function
Selection of Illumination
Brightness
Confirmation of Parameter Setting Contents of the parameters that are set can be
Error History
Confirmation of Software Version
Contents
When Maximum Motor Speed is desired, set the
parameter to
and set the maximum speed.
* Settable Motor Speed Range is 1,000 - 50,000min
-1
1,000min
increments.
When Maximum Motor Speed is desired, set the
parameter to
and set the maximum speed.
* Settable Motor Speed Range is 1,000 - 50,000min
-1
1,000min
increments.
The following Rotation Speed options can be selected
when control mode is AUTO.
: Analog Signal 
: Speed Point Signal
* When
is selected, use External Input/Output
Connector A ③ Pin No. 23 (VR1), No. 3 (VR2).
* When
or
is selected, use External Input/
Output Connector A ③ Pin No. 17 (SEL0), No. 5 (SEL1).
When control mode is in AUTO, please set the parameter
to
and set the desired rotating direction of the motor.
Activate Pin 2 to set a reverse direction along with the
start command.
* Clockwise rotation (FWD) + START/STOP
...External Input/Output Connector A Pin No. 14
(START)
* Counterclockwise rotation (REV) + START/STOP
...External Input/Output Connector A Pin No. 2 (DIR_IN)
If you want to start the motor without supplying cooling
air, please set the parameter to
parameter, motor speed will be limited to 30,000min
(rpm).)
When using the Motor Speed Control Voltage Signal and
-1
a 30,000min
motor, in AUTO Mode, set the parameter
to
.
When using the 50,000min
.
When using the Emergency Stop Selection Mode, please
set the parameter to
When the parameter is set to
Output Connector B ④ Pin No. 1 (EMG - INA) and No. 9
(EMG - INB).
Select the brightness of the blue illumination on the
Control Panel ② and the bottom of CONTROLLER.
confirmed. (
-
.) (No parameter setting is
necessary).
Error code history of the last 5 error events can be
confirmed. (No parameter setting is necessary).
Shows the Software Version number of the
CONTROLLER.
: Pulse Signal
. (When set this
-1
motor, set the parameter to
.
, use External Input/
Default
-1
in
-1
in
-1
or
97