Motor Temperature Sensor Cable; Removal And Installation; Figure 102 - Feed Through Connector; Figure 103 - Motor Temperature Sensor Cable - Danfoss Turbocor VTT Series Service Manual

Variable twin turbo compressors
Table of Contents

Advertisement

Figure 102 - Feed Through
Connector
3.7.1.9 Motor
Temperature Sensor
Cable
Figure 103 - Motor
Temperature Sensor Cable
3.7.1.9.1 Removal and
Installation
90 of 165
M-SV-VT-001-EN Rev. A
Compressor Components
The motor temp sensor cable connects the motor temperature sensor to the CCM.
Removal:
1. Isolate the Compressor power as described in the
section of this manual.
2. Remove the Service Side Cover.
3. Locate and remove the connector from MOT RTD (J12) located on the top-left corner of the CCM
Board.
5
7
8
6
4
11
3
10
9
2
1
"Electrical Isolation of the Compressor/VFD"