FUNCTION
SELECTING
MODE
F-03
Sensitivity
(See below figures)
registering
(1) Rated output
calibration
(2) Rated capacity
(3) Decimal point position
(4) Enable/disable the key code
<To enable the key code>
<To disable the key code>
After the settings, the key code is disabled. You are able to
update the calibration value without entering the key code.
Key operation and WGA-680A movement
in SETTING mode
Set the rated output (mV/V)
of the transducer and
press the SET key.
Range: -3.2000 to 3.2000 (Initial value: 2.0000)
Set a desired numeric value
(rated capacity) to be indicated
and press the SET key.
Range: ±99999 (Initial value: 4000)
Set a decimal point position
and press the SET key.
Then, the calibration value is updated.
The "F00000" appears.
After enabling or disabling the key code, the new
calibration value appears.
The "00000" is displayed at the
end.
In this status, set the "00628"
or "11111"and press the SET key.
Then, the calibration value is
updated.
After the settings, the key code is enabled. To update the
calibration value next time, you are required to enter the
key code.
To disable the key code, execute the "F-12".
The "00000" is displayed at the
end.
Press the SET key.
Then, the calibration value is updated.
decimal point position
40
IM-A-1048H
Functional description,
supplements
A function that conducts
calibration by registering
the rated output and rated
capacity of the transducer
without applying the actual
load.
For details, see "4-4-2.
Sensitivity
REGISTERING
CALIBRATION".
How to set disable/enable
the key codes is same as
"F-02:
Actual Load Calibration".
The "00628" and "11111"
are key codes. The key
codes prevents the
calibration values from
changing due to
malfunctions.