KYOWA WGA-680A Series Instruction Manual page 42

Instrumentation amplifier
Hide thumbs Also See for WGA-680A Series:
Table of Contents

Advertisement

FUNCTION
SELECTING
MODE
F-04
Displays the following items (1). (2). (3).
Hold mode
After setting (1).(2).(3), Displays the following items
(1) Hold Mode
(2) Display mode
(3) Comparison Mode
Select and change values in items (1), (2), and (3) and press
the SET key.
(4) Delay time
(5) Detect time
F-05
Self-check
The "...." is displayed.
To execute the self-check, press the SET key. All LEDs
flicker. The self-check results is displayed as described at
the right.
Key operation and WGA-680A movement
in SETTING mode
0: Tracking (Initial value)
1: Arbitrary point hold
2: Peak Hold
3: Interval-specified peak hold
4: Time-specified peak hold
5: Bottom hold
6: Interval-specified bottom hold
7: Time-specified bottom hold
8: Peak-to-peak hold
9: Interval-specified peak-to-peak hold
A: Time-specified peak-to-peak hold
0: Normal display mode (initial value)
1: Hold display mode
0: Normal comparison mode (initial value)
1: Hold comparison mode
The pre-set delay time is
displayed.
Range: 0.00 to 9.99 (sec.) (Initial value: 0.00)
After changing the value, press the SET key.
The pre-set detect time is
displayed.
Range: 0.01 to 9.99 (sec.) (Initial value: 0.01)
After changing the value, press the SET key.
If faulty self-check results is displayed on the indicator,
contact KYOWA or our representatives.
(1) (2) (3)
41
IM-A-1048H
Functional description,
supplements
This function sets various
hold functions.
For details, see "4-10.
HOLD FUNCTIONS".
Delays the start of holding
intervals for the delay
time.
Sets the detecting interval
time of the time-specified
peak hold, time-specified
bottom hold, and time-
specified peak-to-peak
hold.
A function that checks the
internal memory and
displays the checked
results.
Good: Normal
E-01: RAM failure
E-02: Flash memory
failure