No.
Functions
Initialize
F-16
RS
communication
settings
F-17
Device ID
F-18
CC-Link
F-19
Numeric value
registering
calibration
F-20
Operation
pattern
F-21
Updating rate of
displaying
values
F-22
Level Test
Signals
F-23
[HH]
comparator
(comparator-3)
functions
F-24
[HI] comparator
(comparator-1)
functions
F-25
[LO]
comparator
(comparator-2)
functions
F-26
[LL] comparator
(comparator-4)
functions
F-27
Display
stability
Parameters
Digits
Options/ranges
Zero-point
-3.2000 to +3.2000
output value
Operation
10e0
0
pattern
1
2
3
Updating
10e0
0
rate
1
2
3
4
5
6
7
Display
10e0
0
additional
function
1
Level Test
-99999 to +99999
values
Level Test
10e0
0
ON/OFF
1
1
"High limit"
10e0
0
or "Low
1
limit"
"High limit"
10e0
0
or "Low
1
limit"
"High limit"
10e0
0
or "Low
1
limit"
"High limit"
10e0
0
or "Low
1
limit"
Disable/
10e0
0
Enable
1
Initial
values
0.0000
Pattern 0
0
Pattern 1
Pattern 2
Pattern 3
15.60 times/sec
0
7.80 times/sec
3.90 times/sec
1.95 times/sec
0.98 times/sec
0.49 times/sec
0.24 times/sec
0.12 times/sec
Disabled
0
Enable
0
OFF
0
ON
Low limit
High limit
0
Low limit
High limit
0
Low limit
High limit
1
Low limit
High limit
1
Low limit
Disable
0
Enable
51
IM-A-1048H
Remarks
For details, see the
"INSTRUCTION MANUAL (FOR
BCD/RS-232C/RS-485/TEDS
OPTIONS)".
For details, see the
"INSTRUCTION MANUAL (FOR
BCD/RS-232C/RS-485/TEDS
OPTIONS)".
For details, see the
"INSTRUCTION MANUAL (FOR
CC-LINK OPTION)".
The ZERO indicated value that is
registered at calibration.
Selects the pattern of comparator
values from registered 4 patterns.
Thinning: 1/256 time, 64msec
Thinning: 1/512 time, 128msec
Thinning: 1/1024 time, 256msec
Thinning: 1/2048 time, 512msec
Thinning: 1/4096 time, 1024msec
Thinning: 1/8192 time, 2048msec
Thinning: 1/16384 time, 4096msec
Thinning: 1/32768 time, 8192msec
Outputs the LEVEL TEST values
only.
Outputs a value (current indicated
value + LEVEL TEST value).
Turns OFF the LEVEL TEST
values.
Turns ON the LEVEL TEST values.
Assign "0: High limit" or "1: Low
limit" of the [HH] comparator
(comparator-3).
Assign "0: High limit" or "1: Low
limit" of the [HI] comparator
(comparator-1).
Assign "0: High limit" or "1: Low
limit" of the [LO] comparator
(comparator-2).
Assign "0: High limit" or "1: Low
limit" of the [LL] comparator
(comparator-4).