Connecting The Topside System Components; Connecting The Tpu And The Sonarpro Workstation - Klein 4000 Series Operation And Maintenance Manual

Table of Contents

Advertisement

3-12
CHAPTER 3 Setup and Test
DEBUG:
NAV:
120/240 VAC:
12 VDC:
3.6

Connecting the Topside System Components

The topside system components are connected using KMS or user supplied cables.
Two system configurations are included, one that includes the TPU and the
SonarPro Workstation, and the other that includes the SP-III TPU and the laptop
computer.
3.6.1
The following supplied cables are used to connect the TPU and the SonarPro
Workstation:
• Ethernet crossover cable
• AC power cords (2)
• Deck cable
or damage to the towfish or to the TPU/SP-III TPU electronics, or to both. For the
location of the power switches, refer to "Topside System Controls and Indicators" on
page 3-17.
To connect the TPU and the SonarPro Workstation:
Connect the Ethernet crossover cable to the ETHERNET connector on the
1.
TPU and to either one of the two the ETHERNET connectors on the SonarPro
Workstation.
Connect the monitor to the DVI connector on the SonarPro Workstation and
2.
connect the monitor power supply to the AC power source.
Series 4000 Sonar System Operations and Maintenance Manual
DB9 female connector that connects to a serial port
of a computer and is available for factory use and
troubleshooting purposes. The baud rate is 9600.
DB9 female connector that is used to input
navigation data. The baud rate is 4800.
3-pin bulkhead connector that connects to an
88–264 VAC, 47–63 Hz power source.
4-pin bulkhead connector that connects to a 12 VDC
power source.

Connecting the TPU and the SonarPro Workstation

WARNING Before connecting the topside system components, verify that
the TPU or the SP-III TPU is turned off and that its power cord is
disconnected. Failure to follow this practice may result in personal injury
P/N 11210094, Rev. 01

Advertisement

Table of Contents
loading

Table of Contents