2.2

Technical data

Technical data
Number of inputs
Measuring range
Supply voltage
U
EXCITE
Sensor state monitoring
Supply current I
EXCITE
Input filter limit frequency
Max. sampling rate
Input
AC coupling
Resolution
Measuring error
Supply voltage for electronic
Current consumption via E-bus
Configuration
Weight
Permissible ambient temperature range during
operation
Permissible ambient temperature range during
storage
Permissible relative humidity
Dimensions (W x H x D)
Mounting [} 31]
Vibration/shock resistance
EMC immunity/emission
Protection class
Installation position
Approval
EL3632
EL3632
2
preset ±5 V up to 25 kHz, ±250 mV up to 10 Hz
24 V
via power contacts
DC
U
-1 V typ.
V
yes, through monitoring of the bias voltage
typ. 2 mA/4 mA/8 mA (separately adjustable for both
channels)
analog parameterisable 5
25 KHz
typ. 0.05 Hz high-pass
50 kSamples/s
single ended
0.05 Hz typ.
16 bit
0,5%
via the E-bus
typ. 220 mA
via TwinCAT System Manager
approx. 65 g
0°C ... + 55°C
-25°C ... + 85°C
95 %, no condensation
approx. 15 mm x 100 mm x 70 mm (width aligned:
12 mm)
on 35 mm mounting rail conforms to EN 60715
conforms to EN 60068-2-6 / EN 60068-2-27,
see also installation instructions for terminals with
increased mechanical load capacity [} 34]
conforms to EN 61000-6-2 / EN 61000-6-4
IP20
variable
CE
cULus [} 40]
ATEX [} 39]
Version: 2.8
Product overview
th
order low-pass filter up to
13

Advertisement