Maintaining The Fuel/Water Separator - Husqvarna Wacker Neuson CRT60-74LX Operator's Manual

Ride-on trowel
Table of Contents

Advertisement

Maintenance
Continued from the previous page.
4. Insert the new hydraulic oil filter into the filter canister.
5. Twist the canister clockwise onto the housing, and tighten the hex stud using the
wrench.
6. Install the access panel.
6.11

Maintaining the Fuel/Water Separator

The fuel/water separator removes water from the fuel supply. As fuel flows through
the separator element, removed water collects in the bowl.
Required maintenance includes draining the bowl as needed. If the water in fuel
indicator light illuminates, the separator should be drained as soon as possible.
When
■ Drain the fuel/water separator when the bowl is full of water.
Requirements ■ Machine shut down
■ Plastic cloth and a container of sufficient volume to collect drained water
Note: Collect, store and dispose of drained water in accordance with current
environmental protection regulations.
Location
The fuel/water separator (a) is located beneath the operator's foot platform.
b
To access the fuel/water separator, remove the access panel (b).
Procedure
Perform the procedure below to drain the bowl.
1. Place a collection container beneath the bowl.
2. Loosen the wing nut (c) without removing it.
3. Drain any water present.
4. Tighten the wing nut as soon as fuel begins to flow.
a
74
CRT60-74LX
c
wc_gr012731
wc_tx004561gb.fm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents