Cleaning The Radiator Filler Cap - Husqvarna Wacker Neuson CRT60-74LX Operator's Manual

Ride-on trowel
Table of Contents

Advertisement

Maintenance
6.13

Cleaning the Radiator Filler Cap

When
Every 500 hours of service or yearly
Requirements ■ Machine shut down
■ Engine cool
Procedure
Perform the procedure below to clean the radiator filler cap.
WARNING
Burn hazard. At operating temperature, engine coolant is hot and under pressure. It
can cause severe personal injury.
► Remove the radiator filler cap only after the engine has been shut down and is
cool.
1. Open the engine compartment.
2. Slowly remove the radiator filler cap (a) to relieve pressure.
CAUTION
Burn hazard. Coolant can contain alkali.
► Avoid coolant contact with skin and eyes.
3. Clean the radiator filler cap with a clean cloth.
4. Inspect the radiator filler cap for damage. Replace the cap if it is damaged.
5. Reinstall the radiator filler cap.