Continued from the previous page.
Stopping the
Perform the procedure below to stop the trowel.
Engine
1. Release pressure on the foot pedal.
2. Return joysticks to their neutral positions.
3. Set engine speed to low idle.
4. Allow engine to idle for at least 5 minutes
5. Turn the key to the OFF position.
NOTICE
■ Do not turn off the engine when the engine is running at FAST speed.
■ Overheating and turbocharger damage may occur if the engine is stopped
before the cool-down idling time period.
5.16

Operating Guidelines

Follow the guidelines below to use your Ride-On Trowel to its fullest capacity.
■ Steer the machine in the direction that the operator is facing. This method allows
the operator to finish the widest possible area, while giving the operator an
excellent view of the slab surface to be troweled.
■ When the machine reaches the end of the slab:
■ Make a 180° U-turn and repeat the straight line of direction to the other end
■ Or, move the machine laterally (sideways) and then travel backward to the
NOTICE
■ Only experienced concrete finishers should operate the trowel.
■ Do not use excessive pressure on the joysticks. Excessive pressure does not
improve the response time of the machine and can damage the steering
controls.
■ Attempting to use the trowel too early in the curing state of the concrete may
result in an undesirable finish.
of the slab.
other end of the slab.