Servicing The Air Cleaner - Husqvarna Wacker Neuson CRT60-74LX Operator's Manual

Ride-on trowel
Table of Contents

Advertisement

CRT60-74LX
6.6

Servicing the Air Cleaner

The air cleaner assembly (a) consists of a filter element (b) housed inside the air
cleaner body. Snap clamps fasten the cover (d) to the body. An ejection valve (e)
removes large particulates and moisture.
When
■ Check the condition of the air filter element every day before operating the
machine.
■ Clean the air filter element every 250 hours or when error code SPN 107
appears on the instrument display. Replace the element every year if it becomes
damaged or heavily soiled.
Note: Possible errors are displayed in the instrument display for a few seconds
when the machine is started. For more information about the instrument display
pages see the Controls chapter.
Requirements ■ Machine shut down
■ New air filter element (if required)
NOTICE: Do not use the air filter as a starting aid (e.g., ether) intake.
Procedure
Perform the procedure below to clean the air cleaner.
1. Lift the latch and turn to remove the cover (d).
2. Remove the filter element (b) from the air cleaner body.
3. Clean the filter element by repeatedly tapping the front of the filter several times
against a flat surface.
NOTICE: Do not use compressed air to clean the element.
This procedure continues on the next page.
wc_tx004561gb.fm
a
67
d
e
b
Maintenance
wc_gr012740