Husqvarna Wacker Neuson CRT60-74LX Operator's Manual page 98

Ride-on trowel
Table of Contents

Advertisement

Diagnostic Trouble Codes (DTC)
Error Code
SPN
FMI
1639
6
1639
3
1639
4
1639
31
1762
4
1762
3
2791
3
2791
4
2791
2
2791
2
2791
14
2791
2
2791
7
2791
31
2791
13
2802
13
2802
11
2802
9
2802
31
2802
12
2802
14
3349
9
3349
10
3349
2
3509
3
3509
4
3510
3
3510
4
4082
3
4082
4
Coolant fan low speed relay short to GND
Coolant fan high speed relay short to battery
Coolant fan high speed relay short to GND
Electric fan open load/short to GND/short to battery
Hydraulic pressure sensor signal too low
Hydraulic pressure sensor signal too high
EGR (exhaust gas recirculation) lift sensor signal too high
EGR (exhaust gas recirculation) lift sensor signal too low
EGR feedback error
EGR motor drive circuit invalid
EGR battery/motor failure (for CAN)
EGR no transmission/not received failure (for CAN)
EGR valve stick/initialization failure (for CAN)
EGR valve temperature failure (for CAN)
EGR cleaning failure (valve stuck open/poppet much lower than normal)
QR data is not written
QR data error
QR definition error (definition concerning QR correction is not right)
CPU fault; watchdog IC fault
CPU fault; main CPU fault
Check sum error—flash area
TSC1 Time out error
TSC1 Rolling count test
TSC1 Checksum test
Battery 5V reference 1 circuit high (5V power supply for sensor)
Battery 5V reference 1 circuit low (5V power supply for sensor)
Battery 5V reference 2 circuit high (5V power supply for sensor)
Battery 5V reference 2 circuit low (5V power supply for sensor)
Electric lift pump relay short to battery
Electric lift pump relay short to GND
Description
98
CRT60-74LX
wc_tx004003gb_FM10.fm

Hide quick links:

Advertisement