Maintenance
Continued from the previous page.
6. Open the radiator filler cap.
7. Place a suitable container underneath the machine.
8. Open the drain valve (b) on the bottom of the radiator and allow the cleaner to
drain into a suitable container.
Note: Collect, store and dispose of all used coolant in accordance with current
environmental protection regulations.
9. Flush the cooling system with water until the draining water is transparent.
Filling
Follow the procedure below to fill the cooling system.
1. Close the radiator drain valve.
2. Add the recommended amount of coolant to the radiator.
3. Start the engine.
4. Leave the radiator fill cap off until the thermostat opens and the coolant level is
stabilizes.
5. Maintain the coolant level to 2.54 cm (1 in.) below the shoulder of the fill pipe.
6. Inspect the radiator filler cap and filler cap seal for damage. Clean the radiator
filler cap or replace it if necessary. See Cleaning the Radiator Filler Cap.
7. Reinstall the radiator filler cap.
78
CRT60-74LX
wc_tx004561gb.fm