socomec ATyS s Instruction Manual page 19

Automatic transfer switching equipment
Hide thumbs Also See for ATyS s:
Table of Contents

Advertisement

9
10
11
8
7
6
5
4
3
2
1
25
24
ATyS p
ATyS p
ATS CONTROLLER
ATS CONTROLLER
ATyS p
Dual auxiliary supply:
Dual auxiliary supply:
Uc 208-277V~ +/-20% 50/60Hz
Uc 208-277V~ +/-20% 50/60Hz
Power comsumption: 22VA
ATS CONTROLLER
Power comsumption: 22VA
ATS CONTROLLER
Dual auxiliary supply:
See instruction sheet
Uc 208-277V~ +/-20% 50/60Hz
Dual auxiliary supply:
See instruction sheet
Power comsumption: 22VA
Uc 208-277V~ +/-20% 50/60Hz
Power comsumption: 22VA
See instruction sheet
See instruction sheet
1. MANUAL Mode LED indication. (Yellow
steady light when in Manual Mode).
2. AUTO Mode LED indication Green steady
light when in Auto mode with no timers
running.
Green flashing light when in Auto with timers
running.
3. LOCAL / REMOTE CONTROL Mode LED
indication.
Yellow steady light when in Local / Remote
control mode.
Remote control mode is achieved with the
Auto/Manu selector switched to Auto and
terminals 312 closed with terminal 317.
Remote control orders are received through
closing 314 to 316 with 317.
REMOTE Control is also achievable through
Easy Config ATyS p software when
connected to the product through Ethernet or
MODBUS. (Optional modules). Local Control
selectable and operable through the ATyS
p keypad.
4. TEST ON LOAD CONTROL Mode LED
indication. (Yellow steady light when in TON/
EON mode)
5. TEST OFF LOAD CONTROL Mode LED
indication. (Yellow steady light when in TOF/
EOF mode).
6. Load Supply On LED. (Green when the load
is supplied).
7. Switch 1 LED position indication. (Green
when in position 1).
8. Source supply I availability LED indication.
(Green when supply I voltage is within the
set limits).
9. Zero position LED indication. (Yellow when
in position 0).
10. Switch 2 LED position indication. (Green
when in position 2).
ATYS p - 542001E - SOCOMEC
12
ATyS p
23
22
11. Source supply II availability LED indication.
(Green when supply II voltage is within the
set limits).
12. LCD Display Screen : (Status,
measurement, timers, counters, events,
faults, programming .... )
13. MODE key to shift between operation
modes.
14. Navigation Keys to browse through the
ATyS p menus without software.
15. FAULT LED indication. (Red steady light
in case of an ATS controller internal fault.
Switch the product from Auto to Manual
and back to Auto to reset a fault condition).
16. READY LED indication. (Green steady
light : Product is powered and in AUTO,
Watchdog OK, The Product is Available to
changeover).
17. Enter Key used to enter Prog Mode (Press
and hold for 5 seconds) and to validate the
settings programmed through the keypad.
18. ESC key used to escape from a specific
screen up to the main menu.
19. Lamp test key to check the LED's and LCD
screen.
20. Green LED Indication: Power
21. Red LED Indication: Product Unavailable /
Manual Mode / Fault Condition
22. Auto / Manual mode selector switch
(Key version available as an option)
23. Padlocking facility
(Up to 3 padlocks of dia. 4 - 8mm)
24. Emergency manual operation shaft location
(Accessible only in manual mode)
25. Switch position indication window:
I (On switch I) O (Off) II (On switch II).
STEP 7A
AUT Mode
(Automatic Control)
Ensure that the emergency handle is
not inserted in the product and turn
the mode selector to the AUT position.
LED "Power" Green: ON
LED Manuel/Default: OFF
U
F
Un
N° PP / PN
N°: Δ
Δ
%
1: 220 / 127
1:
5
3
13
2: 380 / 220
2:
6
3
3: 400 / 230
3:
7
4
4: 415 / 240
4:
8
4
5: 480 / 277
5:
9
5
6:
10
5
STEP 7B
14
6: 208 / 120
7:
11
6
AUT Mode
7: 220 / 127
8:
12
6
8: 230 / 132
9:
13
7
9: 240 / 138
10:
14
7
(Remote Control)
10: 380 / 220
11:
15
8
11: 400 / 230
12:
16
8
12: 415 / 240
13:
18
9
13: 480 / 277
14:
20
10
15
PROG
Impulse logic
1
2
Set Dip
3
Set Pot
order I
Ready !
Press
5
Press
4
order 0
16
AUT
60ms
2s
PROG
PROG
order II
17
U
F
Un
N° PP / PN
N°: Δ
Δ
%
position I
1: 220 / 127
1:
5
3
2: 380 / 220
2:
6
3
3: 400 / 230
7
4
3:
4: 415 / 240
4:
8
4
18
5: 480 / 277
5:
9
5
position 0
6:
10
5
6: 208 / 120
7:
11
6
7: 220 / 127
12
6
8:
8: 230 / 132
9:
13
7
19
position II
9: 240 / 138
10:
14
7
10: 380 / 220
11:
15
8
11: 400 / 230
12:
16
8
12: 415 / 240
18
9
Imp. ≥60ms
13:
13: 480 / 277
14:
20
10
PROG
1
2
Set Dip
3
Set Pot
To enable control, close contact 312 with 317.
For contactor logic bridge contact 316 with 317.
Ready !
5
4
Press
Press
20
To operate: close the contact corresponding to
AUT
60ms
2s
PROG
PROG
the desired position.
To force the product to 0 position "OFF" bridge
contact 313 with 317.
21
STEP 7C
Manual Mode
II
U
F
Un
N° PP / PN
N°: Δ
Δ
%
1: 220 / 127
1:
5
3
2: 380 / 220
2:
6
3
3: 400 / 230
3:
7
4
4: 415 / 240
8
4
4:
5: 480 / 277
5:
9
5
6:
10
5
6: 208 / 120
7:
11
6
7: 220 / 127
8:
12
6
8: 230 / 132
13
7
9:
9: 240 / 138
10:
14
7
0
10: 380 / 220
11:
15
8
11: 400 / 230
12:
16
8
12: 415 / 240
13:
18
9
13: 480 / 277
20
10
14:
PROG
1
2
Set Dip
3
Set Pot
Ready !
Press
5
Press
4
AUT
60ms
2s
PROG
PROG
I
Padlocking Mode
STEP 7D
(as standard : in position O)
READY
A: 3 Ph
REMOTE CONTROL
B: 1 Ph
AUT
PROG
C: Neutral
OK
D: Neutral
AUT
READY
A: 3 Ph
REMOTE CONTROL
B: 1 Ph
AUT
C: Neutral
PROG
XXX
OK
D: Neutral
Motorised Changeover Switch
1600A
Contactor logic
Ref : 95054160
ATyS
AUT
Ø 4 ... 8mm
maintened
XXX
Motorised Changeover Switch
1600A
Ref : 95054160
ATyS
Ø 4 ... 8mm
READY
A: 3 Ph
REMOTE CONTROL
B: 1 Ph
AUT
PROG
C: Neutral
D: Neutral
OK
AUT
AUT
XXX
Motorised Changeover Switch
1600A
Ref : 95054160
ATyS
Ø 4 ... 8mm
EN
ATyS t
5
5
1
10
1
10
0
0
20
20
60
60
E:
F:
G: U 10% F 5%
H: U 20% F 10%
ATyS t
5
5
1
10
1
10
0
0
20
20
60
60
POWER
E:
F:
G: U 10% F 5%
H: U 20% F 10%
POWER
ATyS t
5
5
1
10
1
10
0
0
20
20
60
60
E:
F:
G: U 10% F 5%
H: U 20% F 10%
POWER
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Atys sdAtys rAtys dAtys tAtys gAtys p

Table of Contents