M0 (Pwm0 Duty Cycle); M1 (Pwm1 Duty Cycle); Associate Led Blink Time); Rp (Rssi Pwm Timer) - Digi XBee DigiMesh 2.4 User Manual

Radio frequency (rf) module
Table of Contents

Advertisement

AT commands
Parameter range
0 - 0x7FFF (bit field)
Default
0x1FFF

M0 (PWM0 Duty Cycle)

The duty cycle of the PWM0 line (pin 6).
Use the P0 command to configure the line as a PWM output.
Parameter range
0 - 0x3FF
Default
0

M1 (PWM1 Duty Cycle)

The duty cycle of the PWM1 line (pin 7).
Use the P1 command to configure the line as a PWM output.
Parameter range
0 - 0x3FF
Default
0
LT (Associate LED Blink Time)
Set or read the Associate LED blink time. If you use the D5 command to enable the Associate LED
functionality (DIO5/Associate pin), this value determines the on and off blink times for the LED when
the device has joined the network.
If LT = 0, the device uses the default blink rate: 500 ms for a sleep coordinator, 250 ms for all other
nodes.
For all other LT values, the firmware measures LT in 10 ms increments.
Parameter range
0x14 - 0xFF (x 10 ms)
Default
0
RP (RSSI PWM Timer)
The PWM timer expiration in 0.1 seconds. RP sets the duration of pulse width modulation (PWM) signal
output on the RSSI pin. The signal duty cycle updates with each received packet and shuts off when
the timer expires.
When RP = 0xFF, the output is always on.