Pr (Pull-Up/Down Resistor Enable); M0 (Pwm0 Duty Cycle) - Digi XBee-PRO S3 User Manual

900hp/xsc rf modules
Hide thumbs Also See for XBee-PRO S3:
Table of Contents

Advertisement

AT commands

PR (Pull-up/Down Resistor Enable)

The bit field that configures the internal pull-up/down resistor status for the I/O lines. If you set a PR
bit to 1, it enables the pull-up/down resistor; 0 specifies no internal pull-up/down resistor. The
following table defines the bit-field map for PR command.
PR and PD only affect lines that are configured as digital inputs or disabled.
The following table defines the bit-field map for PR and PD commands.
Bit
I/O line
0
DIO4 / AD4 / SPI_MOSI
DIO3 / AD3 / SPI_SSEL
1
2
DIO2 / AD2 / SPI_SCLK
DIO1 / AD1 / SPI_ATTN
3
4
DIO0 / AD0
DIO6 / RTS
5
6
SLEEP_REQUEST
DIN / CONFIG
7
8
DIO5 / AD5 / ASSOCIATE
On/SLEEP
9
10
DIO12 / SPI_MISO
11
DIO10 / PWM0 / RSSI
12
DIO11/ PWM1
DIO7/CTS
13
14
PWM0 / DOUT
Parameter range
0 - 0x7FFF (bit field)
Default
0x7FFF

M0 (PWM0 Duty Cycle)

The duty cycle of the PWM0 line (pin 6).
Use the P0 command to configure the line as a PWM output.
Parameter range
0 - 0x3FF
Default
0
XBee®-PRO 900HP/XSC RF Modules
I/O settings commands