AT commands
Bit
I/O line
12
DIO11
13
DIO7
14
DIO13
15
DIO15
16
DIO16
17
DIO17
18
DIO18
19
DIO19
Parameter range
Through-hole: 0 - 0xFFFF
SMT/MMT: 0 - 0xFFFFF
Default
0xFFFF
Example
Sending the command ATPR 6F turn bits 0, 1, 2, 3, 5 and 6 ON, and bits 4 and 7 OFF. The binary
equivalent of 0x6F is 01101111. Bit 0 is the right-most digit in the binary bit field.

PD (Pull Up/Down Direction)

See
PR (Pull-up/Down Resistor Enable)
Parameter range
Through-hole: 0 - 0xFFFF
SMT/MMT: 0 - 0xFFFFF
Default
0xFFFF

M0 (PWM0 Duty Cycle)

The duty cycle of the PWM0 line (Micro pin 7/SMT pin 7).
If
IA (I/O Input Address)
PWM0 output, incoming AD0 samples automatically modify the PWM0 value. See
Timeout).
To configure the duty cycle of PWM0:
1. Enable PWM0 output (P0 = 2).
2. Change M0 to the desired value.
3. Apply settings (use CN or AC).
Digi XBee® 3 802.15.4 RF Module User Guide
Micro pin
Surface-mount pin
8
8
24
25
3
3
16
17
15
16
14
15
13
14
11
12
for the bit mappings.
is set correctly and
P0 (DIO10/RSSI/PWM0 Configuration)
I/O settings commands
Through-hole pin
7
12
2
N/A
N/A
N/A
N/A
N/A
is configured as
PT (PWM Output