AT commands
Parameter
2
3
4
5
6
Default
1
PD (Pull Up/Down Direction)
The resistor pull direction bit field (1 = pull-up, 0 = pull-down) for corresponding I/O lines that are set
by the PR command.
Parameter range
0x0 - 0xFFFFF
Default
0xFFFFF
PR (Pull-up/Down Resistor Enable)
The bit field that configures the internal pull-up resistor status for the I/O lines.
If you set a PR bit to 1, it enables the pull-up/down resistor
n
If you set a PR bit to 0, it specifies no internal pull-up/down resistor.
n
PR and PD only affect lines that are configured as digital inputs or disabled.
The following table defines the bit-field map for PR and PD commands.
Parameter range
0 - 0xFFFFF (bit field)
Default
0xFFFFF
M0 (PWM0 Duty Cycle)
The duty cycle of the PWM0 line (pin 7).
Use the P0 command to configure the line as a PWM output.
Parameter range
0 - 0x3FF
Default
0
XBee® SX 868 RF Module User Guide
Description
N/A
N/A
Digital output low
Digital output high
UART data present indicator
I/O settings commands