Transtig 4000 / 5000 Mv; Explanation Of Footnotes - Fronius TransTig 2200 Operating Instructions Manual

Tig
Hide thumbs Also See for TransTig 2200:
Table of Contents

Advertisement

TransTig
4000 / 5000 MV
Mains voltage
Mains voltage tolerance
Mains frequency
Mains fuse protection (slow-blow)
Mains connection
Primary continuous power (100% d.c.
Cos phi
Welding current range
Welding current at
Open circuit voltage
Working voltage
Striking voltage (U
The arc striking voltage is suitable for manual operation.
Degree of protection
Type of cooling
Insulation class
EMC emission class
(in accordance with EN/IEC 60974-10)
Dimensions L x W x H (with handle)
Weight
Mark of conformity
1)
Explanation of
footnotes
2)
3)
4)
5)
6)
1)
TIG
Electrode
10 min/40 °C (104 °F) 40% d.c.
10 min/40 °C (104 °F) 45% d.c.
10 min/40 °C (104 °F) 60% d.c.
10 min/40 °C (104 °F) 100% d.c.
TIG
Electrode
)
p
connected to public mains supply with 230 / 400 V and 50 Hz
D.C. = Duty cycle
PCC = interface to the public grid
TIG welding
MMA welding
An emission class A device is not designed for use in residential areas supplied
with power from a public low-voltage grid.
The electromagnetic compatibility can be influenced by conducted or radiated ra-
dio frequencies.
TT 4000 MV
3 x 200 - 240 V
3 x 380 - 460 V
± 10 %
50/60 Hz
63/35 A
Restrictions possible Restrictions possible
2)
)
11.5 kVA
0,99
3 - 400 A
10 - 400 A
2)
-
2)
400 A
2)
360 A
2)
300 A
86 V
10.1 - 26.0 V
20.4 - 36.0 V
9.5 kV
IP 23
AF
F
A
625 / 290 / 475 mm
24.6 / 11.4 / 18.7 in.
42.0 kg
92.6 lb.
S, CE, CSA
TT 5000 MV
3 x 200 - 240 V
3 x 380 - 460 V
± 10 %
50/60 Hz
63/35 A
14.2 kVA
0,99
3 - 500 A
10 - 500 A
500 A
-
440 A
350 A
86 V
10.1 - 30.0 V
20.4 - 40.0 V
9.5 kV
IP 23
AF
F
A
625 / 290 / 475 mm
24.6 / 11.4 / 18.7 in.
42.0 kg
92.6 lb.
S, CE, CSA
109

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents