Tig Setup Menu; Opening The Tig Set-Up Menu; Changing Welding Parameters; Exiting The Set-Up Menu - Fronius TransTig 2200 Operating Instructions Manual

Tig
Hide thumbs Also See for TransTig 2200:
Table of Contents

Advertisement

TIG setup menu

Opening the TIG
set-up menu
Changing weld-
ing parameters
Exiting the set-up
menu
Welding parame-
"Minimum" and "maximum" are used for setting ranges that differ according to power
ters in the TIG set-
source, wirefeeder, welding program, etc.
up menu
tAC
Tacking function for the TIG DC welding process: Duration of the pulsed welding current
at the start of tacking
Unit
Setting range
Factory setting
ON
0.1 - 9.9 s
OFF
80
Press the Mode button to select 2-step mode or 4-step mode
1
Press and hold the "Mode" button
2
Press the right parameter selection button
3
The power source is now in the TIG set-up menu. The last welding param-
eter selected is displayed.
Use the left or right parameter selection button to select the welding pa-
1
rameter that you want to change
Use the adjusting dial to change the welding parameter value
2
Press the Mode button
1
s
OFF / 0.1 - 9.9 / ON
OFF
The pulsed welding current remains in effect until the end of the
tacking operation
The set time begins with the UpSlope phase. After the end of the
pre-set time period, welding continues at a constant current; any
pulsing parameters that have been set are available.
The tacking function is deactivated

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents