Troubleshooting; General; Safety; Displayed Service Codes - Fronius TransTig 2200 Operating Instructions Manual

Tig
Hide thumbs Also See for TransTig 2200:
Table of Contents

Advertisement

Troubleshooting

General

The digital power sources are equipped with an intelligent safety system. This means that
apart from the fuse for the coolant pump, it has been possible to dispense with fuses en-
tirely. After a possible malfunction or error has been remedied, the power source can be
put back into normal operation again without any fuses having to be replaced.

Safety

Work that is carried out incorrectly may result in serious injury or damage to prop-
erty.
► All the work described below must only be carried out by trained and qualified person-
► Do not carry out any of the work described below until you have fully read and under-
► Do not carry out any of the work described below until you have fully read and under-
An electric shock can be fatal.
Before starting the work described below:
► Turn the power source mains switch to the "O" position
► Disconnect the power source from the grid
► Ensure that the power source remains disconnected from the mains until all work has
► After opening the device, use a suitable measuring instrument to check that electrically
An inadequate ground conductor connection can cause serious injury or damage.
The housing screws provide a suitable ground conductor connection for earthing the hous-
ing.
► The housing screws must never be replaced with different screws unless a reliable
Displayed service
If any error message that is not described here appears on the displays, then the fault can
codes
only be fixed by After-Sales Service. Make a note of the error message shown in the dis-
play and of the serial number and configuration of the power source, and contact our After-
Sales Service team with a detailed description of the error.
tP1 | xxx
Note: xxx stands for a temperature value
Cause:
Remedy:
WARNING!
nel.
stood this document.
stood all of the documents relating to the system components, in particular the safety
rules.
WARNING!
been completed
charged components (e.g. capacitors) have been discharged.
WARNING!
ground conductor connection is established.
Overtemperature in the primary circuit of the power source
Allow power source to cool down
91