Transtig 230I - Fronius MagicWave 190 Operating Instructions Manual

Tig
Hide thumbs Also See for MagicWave 190:
Table of Contents

Advertisement

TransTig 230i

Mains voltage U
Mains voltage tolerance
Grid frequency
Mains fuse protection (slow-blow)
Mains connection
Cos phi
Primary circuit S1max. (at 100% D.C.
Welding current range
Welding current at
Open circuit voltage
Working voltage
Striking voltage (U
The arc striking voltage is suitable for manual operation.
Degree of protection
Type of cooling
Overvoltage category
Pollution degree according to IEC 60664 3
EMC Emissions class
Insulation class
Dimensions L x W x H (with handle)
Weight
Marks of conformity
1
1)
TIG
Electrode
TIG
Electrode
10 min/40 °C (104 °F) 35% D.C.
10 min/40 °C (104 °F) 45% D.C.
10 min/40 °C (104 °F) 60% D.C.
10 min/40 °C (104 °F) 100% D.C.
TIG
Electrode
)
p
TT 230i
1 x 230 V
± 15%
50/60 Hz
16 A
3)
Z
on PCC
max
= 273 mOhm
0.99
2)
)
3.36 kVA
3.59 kVA
3 - 230 A
10 - 190 A
2)
5)
190 A
2)
4)
230 A
2)
4)
205 A
5)
155 A
2)
4)
170 A
5)
125 A
97 V
10.1 - 19.2 V
20.4 - 27.6 V
9.6 kV
IP 23
AF
III
6)
A
B
558 / 210 / 369 mm
22.0 / 8.3 / 14.5 in.
16.4 kg
36.2 lb.
S, CE
TT 230i MV
1 x 120 / 230 V
± 15%
50/60 Hz
16 A (U
= 230 V)
1
20 A (U
= 123 V)
1
3)
Z
on PCC
max
= 273 mOhm
0.99
3.36 kVA (U
= 230 V)
1
2.38 kVA (U
= 120 V)
1
3.59 kVA (U
= 230 V)
1
2.32 kVA (U
= 120 V)
1
3 - 230 A
10 - 190 A
5)
190 A
(U
= 230 V)
1
5)
120 A
(U
= 120 V)
1
4)
230 A
(U
= 230 V)
1
4)
170 A
(U
= 120 V)
1
4)
205 A
(U
= 230 V)
1
4)
155 A
(U
= 120 V)
1
5)
155 A
(U
= 230 V)
1
5)
105 A
(U
= 120 V)
1
4)
170 A
(U
= 230 V)
1
4)
130 A
(U
= 120 V)
1
5)
125 A
(U
= 230 V)
1
5)
85 A
(U
= 120 V)
1
97 V
10.1 - 19.2 V
20.4 - 27.6 V
9.6 kV
IP 23
AF
III
3
6)
A
B
558 / 210 / 369 mm
22.0 / 8.3 / 14.5 in.
15.9 kg
35.1 lb.
S, CE
153

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magicwave 230iTranstig 230i

Table of Contents