Transpocket 180 Mv - Fronius TransPocket 150 Operating Instructions Manual

Rod electrode power source
Hide thumbs Also See for TransPocket 150:
Table of Contents

Advertisement

TransPocket
Mains voltage (U
180 MV
Max. effective primary current (I
Max. primary current (I
Max. apparent power (S
Mains fuse protection
Mains voltage (U
Max. effective primary current (I
Max. primary current (I
Max. apparent power (S
Mains fuse protection
Mains voltage (U
Max. effective primary current (I
Max. primary current (I
Max. apparent power (S
Mains fuse protection
Mains voltage tolerance
Mains frequency
Cos phi
Max. permissible mains impedance Z
PCC
Recommended earth-leakage circuit breaker
Welding current range (I
MMA
TIG
Welding current range (I
MMA
TIG
Welding current range (I
MMA
TIG
Welding current for
MMA welding
(U
1
Welding current for TIG
welding
(U
1
)
1
)
1max
)
1max
)
1
)
1max
)
1max
)
1
)
1max
)
1max
1)
), U
2
1
), U
2
1
), U
2
1
10 min/40 °C (104 °F)
= 230 V, fuse = 16 A)
10 min/40 °C (104 °F)
= 230 V, fuse = 16 A)
)
1eff
)
1eff
)
1eff
on
max
= 230 V
= 120 V, fuse = 20 A
= 120 V, fuse = 15 A
1 x 230 V
16 A
25 A
5.75 kVA
16 A slow-blow
1 x 120 V
20 A
28 A
3.48 kVA
20 A slow-blow
1 x 120 V
15 A
19 A
2.28 kVA
15 A slow-blow
-20%/+15%
50 / 60 Hz
0.99
285 mOhm
Type B
10 -180 A
10 - 220 A
10 - 120 A
10 - 170 A
10 - 85 A
10 -140 A
40%
60%
100%
180 A
150 A
120 A
40%
60%
100%
220 A
160 A
130 A
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Transpocket 180

Table of Contents