IFM Electronic AC402S Programming Manual page 45

Smartplc safeline ac4s with fieldbus interfaces
Table of Contents

Advertisement

SmartPLC SafeLine AC4S with fieldbus interfaces
>
Add and configure EtherCAT slave
► Familiarise yourself with the following CODESYS functions!
EtherCAT slave
→ Online help > Fieldbus support > EtherCAT configurator > EtherCAT slave
To configure EtherCAT slaves for the operation with the EtherCAT master of the AC4S:
Requirements:
>
EtherCAT master is added to the project and configured
>
Device description file of the EtherCAT slave has been downloaded (→ manufacturer's website).
1
Optional: Add EtherCAT slave to the device repository
► Select [Tools] > [Device Repository...]
>
Window [Device Repository] appears.
► Click on [Install...].
>
Window [Install Device Description] appears.
► Select the device description of the EtherCAT slaves and click on [Open].
>
CODESYS installs the device in the device repository.
2
Add EtherCAT slave
► In standard area of device tree: Right-click on [EtherCAT_Master (EtherCAT Master)]
► In the context menu: Select [Add device...]
>
Window [Add Device] appears.
► Select the requested EtherCAT slave in the [Device] area.
► Click on [Add Device] to add the selected device to the project.
► Click on [Close] to close the window.
>
CODESYS adds the EtherCAT slave to the project.
3
Configure EtherCAT slave
► In standard area of device tree: Double click on the added EtherCAT slave.
>
The editor window shows the configuration options of the device.
► Configure EtherCAT slave as requested.
(→Add EtherCAT master