SmartPLC SafeLine AC4S with fieldbus interfaces
>
Parameter data
Parameter
Data type
ASi_SlaveAdr
INT
ASi_Master
INT
DisableLogging
BOOL
EnableStartupTest
BOOL
SynchTime
WORD
* ...
Default value
>
Process data
Parameter
Data type
S_IN_dependent
SAFEBOOL
Description
Address of the AS-i slave
AS-i master to which the AS-i
slave is connected
Transmission of the event
messages to OSC of the device
Control execution of the start-up
test
Synchronisation time
Description
Safe process signal
Possible values
1
Slave address 1
...
...
31
slave address 31
1
AS-i Master 1
2
AS-i Master 2
FALSE
Following states of the state diagram
are transmitted to the OSC: *
S_ON
S_OFF
S_Test
S_Error
S_Init (HW-Error)
TRUE
Following states of the state diagram
are transmitted to the OSC:
S_Test
S_Error
S_Init (HW-Error)
FALSE
No start-up test *
TRUE
Start-up test is executed; slave waiting
for start-up sequence OFF  ON
0
Infinite
250
250 milliseconds
...
...
500
500 milliseconds *
...
...
60000
60000 milliseconds
Possible values
FALSE
Safe OFF
TRUE
Safe ON