SmartPLC SafeLine AC4S with fieldbus interfaces
>
Example: Read LCEMS, LCEAS and LDAE of AS-i Master 2
Task: Read the error lists LCEMS, LCEAS and LDAE of the AS-i Master 2 with the FB
ACnnnn_SysCmd.
Command type: acyclic data set
Input parameters of the FB:
Parameter
Value
uCommandID
0x0011
uTarget
1
pDataIn
--
uSizeIn
--
pDataOut
arDataOut
uSizeOut
0x000C
Content of arDataOut:
Word no.
Content
1 ... 4
LCEMS (list of configuration errors - missing slaves)
5 ... 8
LCEAS (list of configuration errors - additional slaves)
9 ... 12
LDAE (list of double address errors)
186
Declaration
Corresponding acyclic data set:
DS17 – AS-i Master: Fehlerlisten LCEMS, LCEAS, LDAE
supplement)
Master command (1 = AS-i Master 2))
irrelevant
irrelevant
Variable of the data type Array of Words
contains the return values
Array consists of 12 lines since the data set DS17 has exactly 12 words