IFM Electronic AC402S Programming Manual page 237

Smartplc safeline ac4s with fieldbus interfaces
Table of Contents

Advertisement

SmartPLC SafeLine AC4S with fieldbus interfaces
>
Parameter data
Parameter
Data type
IN_Channel_A
INT
IN_Channel_B
INT
EnableIN_Test
BOOL
DisableLogging
BOOL
EnableStartupTest
BOOL
* ...
Default value
>
Process data
Parameter
Data type
S_IN_forced
SAFEBOOL
>
Description
Local input to which sensor
channel A is connected.
Local input to which sensor
channel B is connected.
Evaluation of a test signal which
was created by a local output
Transmission of the event
messages to OSC of the device
Control execution of the start-up
test
Description
Safe process signal
Possible values
1
Local input IN1
...
...
8
local input IN8
1
Local input IN1
...
...
8
local input IN8
FALSE
Test signal is ignored *
TRUE
Test signal is evaluated
FALSE
Following states of the state diagram
are transmitted to the OSC: *
S_ON
S_OFF
S_Test
S_Error
S_Init (HW-Error)
TRUE
Following states of the state diagram
are transmitted to the OSC:
S_Test
S_Error
S_Init (HW-Error)
FALSE
No start-up test *
Start-up test is executed; slave waiting
TRUE
for start-up sequence OFF  ON
Possible values
FALSE
SAFE OFF
TRUE
Safe ON
43058
43116
237

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac422sAc412sAc432s

Table of Contents