IFM Electronic AC402S Programming Manual page 169

Smartplc safeline ac4s with fieldbus interfaces
Table of Contents

Advertisement

SmartPLC SafeLine AC4S with fieldbus interfaces
>
Output parameters
Parameter
Data type
xReady
BOOL
xBusy
BOOL
xError
BOOL
wDiagnostic
WORD
Diagnostic codes:
0x0000
No specific error is set
0x0001
Transferred values for date/time are invalid and could not be set.
0x0002
NTP active, time could not be adopted.
Description
Signal indicates whether the execution
of the FB is completed.
Signal indicates whether the FB is
being executed.
Signal indicates whether errors
occurred while the FB was executed.
Diagnostic information
Possible values
FALSE
FB is inactive or being
executed.
TRUE
FB execution is completed.
FALSE
FB is deactivated or FB
execution is completed.
TRUE
FB execution has started but is
not yet completed.
FALSE
FB is disabled or is being
executed or FB was executed
without error.
TRUE
An error occurred while the FB
was executed.
→ List below (Diagnostic codes)
42612
169

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac422sAc412sAc432s

Table of Contents