IFM Electronic AC402S Programming Manual page 197

Smartplc safeline ac4s with fieldbus interfaces
Table of Contents

Advertisement

SmartPLC SafeLine AC4S with fieldbus interfaces
>
Input parameter
Parameter
Data type
Enable
BOOL
FB_Type
INT
FB_Number
INT
DiagCode
INT
The diagnostic code of the safety PLCopen FBs are of data type WORD.
>
Output parameters
Parameter
Data type
Ready
BOOL
Error
BOOL
Description
FB activation
ID of the function block (is
assigned by the programmer)
Instance number of the function
block (is assigned by the
programmer)
Diagnostic code of the safety
PLCopen function block
Description
Status of the transmission of the
diagnostic code
Error indication
Possible values
FALSE
FB is deactivated.
TRUE
FB is activated.
0x3D6B
SF_Antivalent
0x5096
SF_EDM
0x50A9
SF_EmergencyStop
0x5151
SF_EnableSwitch
0x516E
SF_Equivalent
0x56DD
SF_ESPE
0x56E2
SF_GuardLocking
0x571A
SF_GuardMonitoring
0x5725
SF_ModeSelector
0x5A03
SF_MutingPar
0x5A3C
SF_MutingPar_2Sensor
0x5BC4
SF_MutingSeq
0x5BFB
SF_OutControl
0x5C48
SF_SafetyRequest
0x5C77
SF_TestableSafetySensor
0x5D8F
SF_TwoHandControlTypeII
0x5DB0
SF_TwoHandControlTypeIII
→ Operating instructions safety PLCopen library in
CODESYS
Possible values
FALSE
At present no transmission request
TRUE
Transmission of the diagnostic code
successfully completed
FALSE
No error occurred during FB
processing
TRUE
Error occurred during FB processing;
transmission of the diagnostic code
failed
43017
43074
197