IFM Electronic AC402S Programming Manual page 174

Smartplc safeline ac4s with fieldbus interfaces
Table of Contents

Advertisement

SmartPLC SafeLine AC4S with fieldbus interfaces
Name
CDI
PCD
InputParam_SA_Slave
InputParam_B_Slave
OutputParam_SA_Slave ARRAY[0..31]
OutputParam_B_Slave
174
Data type
Description
ARRAY[0..63]
Image of the current configuration
OF WORD
data
(CDI = Configuration Data Image)
ARRAY[0..63]
Image of the projected
OF WORD
configuration data
(PCD = Projected Configuration
Data)
ARRAY[0..31]
Input parameters of the S/A slaves
OF BYTE
ARRAY[0..31]
Input parameters of the B slaves
OF BYTE
Output parameters of the S/A
OF BYTE
slaves
ARRAY[0..31]
Output parameters of the B slaves
OF BYTE
Possible values
One word is available per slave:
Bits 0...3 = IO code
Bits 4...7 = ID code
Bits 8...11 = Extended ID1 code
Bits 12...15 = Extended ID2 code
DS11 – Actual configuration data
(CDI)
Each word contains data of one slave:
Bits 0...3 = IO
Bits 4...7 = ID
Bits 8...11 = ID1
Bits 12...15 = ID2
DS12 – Projected configuration data
(PCD)
Each byte contains parameters of one S/A
slave:
Bits 0...3 = P0-P3
Bits 4...7 = reserved
DS13 – Image of the input
parameters of the slaves
(PI), words
0...15
Each byte contains parameters of one B
slave:
Bits 0...3 = P0-P3
Bits 4...7 = reserved
DS13 – Image of the input
parameters of the slaves
(PI),
words 16...31
Each byte contains parameters of one S/A
slave:
Bits 0...3 = P0-P3
Bits 4...7 = reserved
DS14 – Image of the output
parameters of the slaves
(PP), words
0...15
Each byte contains parameters of one B
slave:
Bits 0...3 = P0-P3
Bits 4...7 = reserved
DS14 – Image of the output
parameters of the slaves
(PP), words
16...31

Hide quick links: