SmartPLC SafeLine AC4S with fieldbus interfaces
>
Output parameters
Parameter
Data type
dwLPF_SA_Slaves
DWORD
dwLPF_B_Slaves
DWORD
xReady
BOOL
xBusy
BOOL
xError
BOOL
wDiagnostic
WORD
Diagnostic codes:
0x0000
No specific error is set
0x0F01
Unknown error
0x0F02
Unknown/invalid target
0x0F03
Unknown command ID
0x0F04
Invalid parameters
0x0F05
Timeout during processing
136
Description
List of peripheral faults on S/A slaves.
Each bit represents an AS-i address:
Bit 0 (LSB) = address 0
...
Bit 31 (MSB) = address 31/31A
List of peripheral faults on B slaves.
Each bit represents an AS-i address:
Bit 0 (LSB) = not used
Bit 1 = address 1B
...
Bit 31 (MSB) = address 31B
Signal indicates whether the execution
of the FB is completed.
Signal indicates whether the FB is
being executed.
Signal indicates whether errors
occurred while the FB was executed.
Diagnostic information
Possible values
Per bit:
0
No peripheral fault
1
Peripheral fault detected
Per bit:
0
No peripheral fault
1
Peripheral fault detected
FALSE
FB is inactive or being
executed.
TRUE
FB execution is completed.
FALSE
FB is deactivated or FB
execution is completed.
TRUE
FB execution has started but is
not yet completed.
FALSE
FB is disabled or is being
executed or FB was executed
without error.
TRUE
An error occurred while the FB
was executed.
→ List below (Diagnostic codes)