IFM Electronic AC402S Programming Manual page 192

Smartplc safeline ac4s with fieldbus interfaces
Table of Contents

Advertisement

SmartPLC SafeLine AC4S with fieldbus interfaces
>
Output parameters
Parameter
Data type
Ready
BOOL
Error
BOOL
DiagCode
WORD
Diagnostic codes:
0x8000
Output = ON; HS_ACK = idle
0x8002
Output = OFF; HS_ACK = idle
0x8830
Output = ON; HS_ACK = OK
0x8832
Output = OFF; HS_ACK = OK
0x8840
Output = ON; HS_ACK = nOK
0x8842
Output = OFF; HS_ACK = nOK
0x8850
Output = ON; HS_ACK = RUN
0x8852
Output = OFF; HS_ACK = RUN
>
192
Description
Status of the FB processing
(validity of the output signals)
Error indication
Diagnostic code of the internal
states of the controlled logical
device
Possible values
FALSE
FB not completely processed or
deactivated; signals are invalid
TRUE
FB completely processed; signals are
valid
FALSE
No error
TRUE
Logical device is in the locked error
state S_ERROR
Scope of the diagnostic code depends on the
controlled logical device: Description of the
selected logical device (→
Library
SF_LogicalInterfaces.library
43078
(→ S. 200))