Hot Air Plenum - PSG CADDY MAX CADDY WOOD ADD-ON PF01102 Installation And Operating Instructions Manual

Table of Contents

Advertisement

NOTE:
It is recommended to install an outside air inlet with
a diameter of at least 4" in the room where the
heating appliance is installed (see drawing below).
It is preferable to choose a wall which is not
exposed to dominant winds, depending on the
conditions surrounding your house.
N.B. The owner of the add-on is responsible for the room's air quality in case of negative pressure or
temporary negative pressure.
If there is a fan in the wood storage room, make sure it does not create a depression in the room where the add-on is
installed.
For more information regarding the installation of fresh air intake adapter, refer to the option's manual.

15.14. HOT AIR PLENUM

The hot air plenum coming out of the add-on is to have a minimum height of 24" (610 mm). These dimensions for all
hot air add-on are in accordance with the standards CSA B140.4.
NOTE: TO ENSURE ADEQUATE STATIC PRESSURE, THE SYSTEM SHOULD BE BUILT IN A WAY THAT THE
VOLUME OF COLD AIR RETURN IS AT LEAST EQUAL OR SLIGHTLY HIGHER THAN THE VOLUME OF THE HOT
AIR DISTRIBUTION.
Fresh air
intake
Exterior wall
Insulated pipe
(full length)
Free air
entry
33