8. CHIMNEY AND DRAFT
This add-on must be connected to a chimney certified for use with wood burning heating appliances. A 6-inch chimney
is recommended.
The unit is not to be connected to a chimney flue serving another appliance. If the chimney draft exceeds 0.06 IN.W.C.,
a barometric draft control should be installed on the smoke pipe. Never install a manual damper. The barometric
control must be adjusted so that the maximum draft measured at the add-on outlet does not exceed -0.06 IN.W.C.
Please note that a draft exceeding 0.06 IN.W.C. could produce an uncontrollable fire. On the other hand, the
minimum draft required is 0.04 IN.W.C. The adjustment should in no case be modified to increase combustion.
9. SAFETY RULES
THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE APPLIANCE ALWAYS
OVERRIDES THE INFORMATION PUBLISHED, IN ANY OTHER MEDIA (OWNER'S MANUAL, CATALOGUES,
9.1. GENERAL REQUIREMENTS
•
MAKE SURE THE CHIMNEY OUTLET AND THE PIPES ARE CLEAN AND IN GOOD CONDITION.
•
DO NOT USE CHEMICAL PRODUCTS OR LIQUIDS TO LIGHT THE FIRE.
•
DO NOT BURN WOOD COATED WITH PAINT, GLUE OR CHEMICAL PRODUCTS.
10
WARNING:
FLYERS, MAGAZINES AND/OR WEB SITES).