18.2. CHIMNEY MAINTENANCE

The most efficient way to sweep a chimney is to run a hard chimney sweeping brush. Brush from the top down so
sooth and creosote deposits will detach from the chimney liner and fall down to the bottom of the chimney where it can
be easily removed.
The chimney must be inspected regularly and any creosote build-up must be removed without delay. Monthly cleaning
should be sufficient during cold winter months while more frequent cleaning could be required during milder periods.

18.3. SMOKE PIPE INSPECTION

The smoke pipe must be inspected regularly during the heating season.
The pipe must be examined carefully to detect any defect or damage.
The pipe can be reassembled if no defect is detected and defective pipe must be replaced immediately.
Burn wood only in this add-on.
As a combustible, well seasoned hardwood in 18" to 22" logs works best
Regularly, examine the flue pipes, the joints, and the sealing trims to ensure that the smoke and the combustion
gases are not transported into the air ducting system.

18.4. DOOR GASKET MAINTENANCE

It is important to maintain the door gasket in good condition. After a while, the gasket might sag; a door adjustment
may then be required. If the door adjustment is not sufficient, replace the door gasket with a genuine one.

18.5. DOOR ADJUSTMENT PROCEDURE

1. Unscrew completely the locking pin (see picture below).
2. To increase the pressure of the door on the gasket, turn the handle counter clockwise; to decrease the pressure of
the door on the gasket, turn the handle clockwise until desired pressure is attained.
3. Then, screw back the locking pin about 1/4" deep and make sure you lock it in place with the nut.

19. REPLACEMENT PARTS

Your PSG add-on is designed to burn clean and requires little maintenance. It is recommended to conduct a visual
inspection at least once a month to uncover any damage to the unit. Any defect must be repaired without delay using
genuine PSG replacement parts. You can find a complete list of replacement parts in section 29 - EXPLODED VIEW
AND PART LIST or on our website at www.caddyfurnaces.com.