31. CareTel

1. Remote use of CareTel with GSM phone

To/from CareTel can be sent/received SMS ---messages with a GSM phone. All GSM phones with the SMS ---function can be
used. In the CareTel design has been used Nokia 2110 GSM phone. In the display of this phone can be seen 10 characters
in three lines.
Note! Normally from the GSM phone menu is selected the SMS message typing mode and after typing the message it is sent
to the CareTel system phone. See Instruction Manual of the phone.
Care Tel uses five different message types:
--- Questions
--- Answers
--- Settings (have been fed in the factory)
--- Confirmations
--- Alarm messages (the receiver phone numbers have been fed into the data logger in the factory)
Important! It is possible that with the Care Tel set values have been determined different rights of usage for different GSM
phones. If a question has been sent from a phone, which has not adequate rights, the CareTel does not send an answer
message.
Note! Concerning different measuring logs in the data logger, see page 360/8.
A. Query of one measuring value
Query
ZZ[---H|L|n][---A|PH|PL]
ZZ=name of measuring value. In the CareTel settings there are determined two---letter names for all different
measuring values as follows.:
TE=Temperature Engine, ˚C
TT=Temperature Transmission ,˚C
ME=Moment Engine, %, Sigma ---Power 8750 only
RE=Revs Engine, RPM
RP=Revs PTO, RPM
PH=Pressure Hydraulics (low pressure circuit), BAR
PT=Pressure Transmission, OK/LOW
PE=Pressure Engine, OK/LOW
SP=Sigma ---Power (ETB light), ON/OFF
---H=maximum value
---L=minimum value
---n=which value in order from the last value backwards (in memory 1---195 values)
---A=query is directed to the alarm log (in this log there is stored maximum and minimum values of the criti-
cal limit values)
---PH=query from maximum log
---PL=query from minimum log
Note! if ---A, ---PH or ---PL parameters are not given, the query is directed to the standard log. If the query is
directed to the max. or min. log, parameters ---H, ---L or ---n have no signification.
Care Tel gives value to the asked measurement and, in addition, values to the four previous measurements,
if the query is not directed to the min or max logs.
Exsamples:
TE
Query of five last measurements of engine temperature.
TT ---A
Query of transmission temperature from the alarm log, five last measurements.
PT ---100
Query of transmission oil pressure from standard log, five values from value nr 100 backwards.
Model
1. 4. 1997
443
Code
Page
6000-- 8750
360
3