Query From Special Tracking Log; Control Of Automatic Alarm Messages; Control Of Special Tracking Log - Valtra 6000 Workshop Manual

Hide thumbs Also See for 6000:
Table of Contents

Advertisement

31. CareTel
F. Query from special tracking log
The measuring values, which are gathered in the special tracking log, are initiated with ST message.
Note! In the special tracking is gathered 2000 different measuring values from certain sensor in frequency of
normal standard log. The measuring frequency has been set in the factory. Default value is 10 seconds.
ST [---n]
This question above shows five measuring values from the special tracking log from beginning of measurement
no ---n and backwards. In this log parameter ---n can vary between 1---2000.

Control of special tracking log

One measuring point is switched on to the special tracking mode with ST command.
ST ZZ
In the command above, ZZ is a two---letter name of the measuring point in question.
The STOP command below stops the gathering of data into the special tracking log.
ST STOP
Zeroing of this log is with the CLEAR command below.
ST CLEAR
G. Control of automatic alarm messages
CALL
ID OFF
CALL
ID ON
ID=tractor serial number
OFF=automatic alarm messages are not sent.
ON=automatic alarm messages are sent
When the above shown command has been sent, CareTel sends a confirm (ACK CALL=positive confirm, NACK
CALL=negative confirm. The confirms show also the tractor serial number and running hours.).
Model
1. 4. 1997
447
Code
Page
6000-- 8750
360
7

Hide quick links:

Advertisement

Table of Contents