34. Autocontrol ---III

Error messages in Service Program

Service Program has the following error messages which appear in the MESSAGE WINDOW in the RH side lower corner of the
fault tracing chart. If other error messages appear, switch off current and start from the beginning.
ERROR IN CHECKSUM
PARAMETER REV MISMATCH.
ERROR IN EPROM
AC ---III DOES NOT RESPOND
ERROR IN COMMUNICATION
WRONG NUMBER OF CHAR
ILLEGAL CHAR FOUND
FILE ERROR
If this message appears on the PC display when you are programming the AC---III unit, You
must start from the beginning after switching off and on current.
Parameter file and EPROM have different version numbers.
If You have found an error in EPROM, switch off the AC---III unit for a while and start the
Service Program and try again programming. If this is not enough, change the central
processing unit (ECS). (EPROM=eraseable and programmable read only memory)
Connection between the PC and the AC---III unit does not function. Check the middle cable
and check that the AC---III unit is switched on. Check AC---III fuses.
Switch off the AC---III unit for a while and start the Service program again.
This message appears if You try to copy into the AC---III unit a parameter file which has not
correct number of characters. Program error.
A parameter file includes an illegal character/characters. Only figures 0 ---9 are allowed.
Program error.
If the file does not exist, appears this message on the PC display. Check the parameter file
name. Start from the beginning after turning current off and on.
383
Model
6100E, 8100E
15. 6. 1992
Code
Page
343
3