Checking Switch Panel Of Acd; Measuring Supply Voltage; Checking Lowering Speed Selector S7E; Checking Transport Height Selector S8E - Valtra 6000 Workshop Manual

Hide thumbs Also See for 6000:
Table of Contents

Advertisement

32. ACD electro---hydraulic power lift
F. 1. Checking switch panel of ACD
Remove the switch panel from the lever console (do not
disconnect the connector). Switch on currrent and activate
the ACD power lift. Measure from the terminals on the rear
side of the circuit card (DC).

1. Measuring supply voltage

Picture a) Measure supply voltage between terminals 8 (---)
and 10 (+): Correct value is 9,2 ---9,8 V (DC).
Note! If the measured value is incorrect. the fault lies in the
connectors.

2. Checking lowering speed selector S7E

Picture b) Measure voltage (DC) between terminals 8 and
6 with all selector positions:
Position
Pin 6
1
0,4 ---0,6 V
2
0,9 ---1,3 V
3
1,3 ---1,8 V
4
1,9 ---2,4 V
5
2,8 ---3,5 V
6
3,8 ---4,5 V
7
5,0 ---5,6 V
8
6,9 ---7,4 V
9
9,2 ---9,8 V
Model
1. 4. 1997
8450-- 8750
1. 11. 1998

3. Checking transport height selector S8E

Picture c) Measure voltage between pins 8 and 5 with all
selector positions:
Position
Pin 5
1
0
2
1,1 ---1,5 V
3
2,3 ---2,8 V
4
3,6 ---4,0 V
5
4,8 ---5,2 V
6
6,0---6,6V
7
7,2 ---7,8 V
8
8,5 ---9,1 V
9
9,2 ---9,8 V
4. Draft control selector S9E
Picture d) Measure voltage between pin 8 and 3 with all
selector positions:
Pos.
Pin 3
P
9,2 ---9,8 V
1
4,9 ---5,3 V
2
4,0 ---4,4 V
3
3,0 ---3,5 V
4
2,0 ---2,4 V
5
0,9 ---1,3 V
6
0
311
Code
Page
321
7

Hide quick links: