Connectors; Fieldmaster Components On The Tractor - Valtra 6000 Workshop Manual

Hide thumbs Also See for 6000:
Table of Contents

Advertisement

33. FieldMaster
Picture 2. FieldMaster components on the tractor
1. Display unit (A16). It has in ---built electronics for all func-
tions of FieldMaster.
2. Adapter (A17), which is fitted under the AC/ACD power
lift control panel. The adapter converts signals from the
tractor speed sensors (4, 5) so that the diplay unit can
use them.
3. Rear socket for connecting sensors on implement (X46)
4. PTO shaft rotation speed sensor (same as for AD ---instru-
ment)
5. Gearbox speed sensor (same as for AD ---instrument)
6. Connector to connect auxiliary devices (e.g. PC) (serial
port RS ---232) (X43)
7. Radar (option)
1. 8. 1998

Connectors

X7C: connector for the lift/lower switch of the AC/ACD
power lift. The function includes stopping the area
counters, when the three point linkage is lifted. The
connector is placed in the lever console.
X34: connector for the speed sensors on the tractor (4, 5).
The conncetor is situating in the lever console.
X48: connector of the radar in the lever console. There is
also another connector near the radar.
GR4: FieldMaster earth point in the rear part of the lever
console.
X55: Supply voltage connector in the lever console (same
as for the Agrodata performance monitor).
X1L: via this connector are drawn wires of connector X43.
The connector is situating under the switch panel of
the power lift.
340
Model
Code
6200-- 8750
332
Page
2