37. Autocontrol 5 / 5.2

2. Fault tracing

A. General
AC 5 / 5.2 unit has an in ---built function for self ---diagnosis. If fault/faults appear in the AC 5 when working with a tractor, the
fault code of the fault in question is shown in the diplay. In this instruction is shown a table in which there are listed all fault
codes and corresponding faults. In this way can be localised the fault and possible repair works can be carried out.
In addition, AC 5 / 5.2 unit has an additional diagnostic mode. By pressing certain tractor switches and buttons in a correct
order (instructions later), the display can be activated into the test mode, in which the diplay shows technical values of vari-
ous electrical components when components in question are activated. Later in this instruction are shown tables which show
the correct technical values of the components. These values are compared with the actual signals in the display so that
possible incorrect functions can be verified.
In the same way the diplay unit can be activated into the setting mode, in which can be done various settings of the AC 5
components. The setting instructions are shown later in this instruction. In section 4 (components) are given instructions to
measure with a multimeter. With the aid of these instructions the components can be checked and verified a faulty compo-
nent.
NOTE! On page 370/7 there are shown working orders för the fault tracing.
B. Self---diagnosis
The self ---diagnosis of AC 5 / 5.2 follow up possible faults in the system (when the current is switched on) and show a fault
code, which appears in the lower display block (also a book image and the symbol of the module in the middle display block
are blinking, when the fault code is shown).
FAULT GROUPS:
A: analog input (position and temp. sensors)
P: proportional output (proportional valves)
d: digital input (switches)
F: frequency input (rpm sensors)
L: logical fault (slipping clutch)
All fauts are numbered with running numbers (01---99). In addition, fault type is shown with numbers (1---4).
FAULT CODES: (e.g. P101)
The fault code is shown in the display diagnosis block (lower) in four display segments as follows:
--- The first segment from the left shows the fault group (A, P , d, F or L).
--- The second segment from the left shows the fault type (1 ---4)
--- The two RH side segments show the order number of the fault (01 ---99).
Note! When the fault code is shown, the symbol of the module is shown in the middle block (A=AC 5 / 5.2), which the fault
has been found.
When the self ---diagnosis shows the fault code, the book image is flashing in frequency of 2 Hz. If two or more faults are
found simultaneously, the codes of different faults are shown three seconds by turns. When the current is switched off, the
fault code memory is erased. If a fault code has been found, the driving speed or outdoor temperature cannot be seen in the
lower display block. Also number of the quick ---shift gear cannot be seen.
FAULT GROUP:
P=proportional output
IMPORTANT! Escaping from the fault code mode is done by switching off current with the starter switch, when the fault codes
exit from the display block.
AC 5.2 has a fault code memory, in which there are stored 3 latest fault codes with running hours, see page 371/6.
1. 8. 2000
1. 9. 2002
FAULT TYPES:
1=short circuit or cut
2=cut
3=value not in permissible limits
4=multi ---disc clutch is slipping
Module A=AC 5
Book symbol is shown together
with fault code.
FAULT TYPE: 1=short circuit or cut
FAULT CODE:
01= Proportional valve P1 of DPS
119
Model
Code
Page
370
6250-- 8950
5