5.2

Dimensions

Designation
Wall thickness with render [mm]
Wall opening for wall sleeve
Wall sleeve R-D160x495 (745)
Smart protective hood
Nova protective hood
Flair inner cover V-233x233
incl. render, insulation, masonry and inner structure.
1)
Sectional drawing
10
4
D
Figure 2: Sectional drawing iV-Smart
1 Inner cover base plate
2 Inner cover panel
3 Wall sleeve R-D160
4 Exterior closure: Weather protection
hood
A Inner plaster/internal structure
B Masonry
150
6
5
260
43
C
+
(side view)
iV-Smart
I V- S M A R T+ V E N T I L AT I O N U N I T
Depth/
Width [mm]
length [mm]
> 270
Wall thick-
ness
1)
495 (745)
43
222
23 – 88
279
61
233
2)
opened
2)
7
8
9
3
≥ 270
B
5 Joint tape
6 Thermal accumulator
7 Standard guiding vane (broad)
8 Xenion reversible fan
9 Slim guiding vane
C Insulation
D Render
+
ventilation system
Height
[mm]
285
313
233
1
1 – 2°
61
A
Installation instructions
Ø [mm]
180
160
2
17