Specifications According To Ec Directive For Energy Related Products - inVENTer iV-Smart+ User Manual

Hide thumbs Also See for iV-Smart+:
Table of Contents

Advertisement

S P E C I F I CAT I O N S
3.2
Specifications according to EC Directive for energy related products
+
iV-Smart
, local demand control:
Product fiche iV-Smart
Pt.
Description
a
Supplier's name
b
Supplier's model identifier
SEC class / Specific energy con-
c
sumption [kWh/(m²a)]
d
Typology
e
Type of drive installed
f
Type of heat recovery system
e
Thermal efficiency of heat recovery ƞ
h
Maximum flow rate (supply air) [m³/h]
i
Electric power input [W]
j
Sound power level L
k
Reference flow rate [m³/h]
l
Reference pressure difference [Pa]
m
Specific power input (SPI) [W/m³/h]
n
Control factor
o
Internal/external leakage rate [%]
p
Mixing rate [%]
q
Position of visual filter warning
Regulated supply and exhaust grilles in the facade
r
(one-direction devices only)
s
Internet:
t
Airflow sensitivity [%]
u
Indoor and outdoor air tightness [m³/h]
v
Annual electricity consumption [kWh/(m²a)]
w
Annual heating saved [kWh/(m²a)]
+
iV-Smart
12
[dB (A)]
wa
ventilation system
Installation instructions
+
according to VO 1254/2014 EU, dated 2014-07-11
cold
average
warm
[%]
t
cold
average
warm
Data
inVENTer GmbH
+
iV-Smart
+
iV-Smart
Corner
+
iV-Smart
Ohio
-88.068
A+
-43.952
-18.678
BVU
2
regenerative
87
58
6
44
42
0
0.15
0.65
n. a.
n. a.
Controller
no
www.inventer.eu
29.4
6.3
0.87
90.25
46.13
20.86

Hide quick links: