Event Memory Recall mode

This function allows you to playback the last 254 system events that occurred.
Event Memory recall mode reports all alarms and each arming or disarming of the system and
helps in troubleshooting system faults.
The events are shown using the keypad indicators. Defined events are shown using keypad
indicators.
To enter Event memory Recall mode:
Enter your code + [5] and press #. Two beeps sound. The events are played back by the
keypad indicators in reverse chronological orer.
Example:
If the events occurred in the following order:
Sequence
1
2
3
4
The alarm memory is played back in this order:
Sequence
1
2
3
4
Each event is indicated by a beep and a lit indicator.
Resetting a disarmed 24-Hour alarm is indicated by a beep only.
After the last event, two beeps sound to indicate the end of the playback.
You can stop the replay at anytime by pressing [#].
If the system is armed in STAY mode, the STAY indicator shows the event memory playback.
If the control panel is powered down the memory of all events is saved.
Bosch Sicherheitssysteme GmbH
Event
System armed in AWAY mode
Alarm in Zone 3
Alarm in Zone 4
System disarmed
Indication
All indicators off
Zone 4 and AWAY indicators light
Zone 3 and AWAY indicators light
AWAY indicator lights
User Guide
Event Memory Recall mode | en
Event
System disarmed
Alarm in Zone 4
Alarm in Zone 3
System armed in AWAY mode
F.01U.249.500 | V4 | 2011.12